کالـــیبراتورهــای ســری 718
(Fluke 718 Pressure Calibrator)
img1

 

 

بررسی اجمالی

Fluke 718 Pressure Calibrator

مشخصات فنی

Technical Specifications
Fluke 718 Series
Measure pressure (Internal sensor)
Accuracy 0.025% full scale
Functions Zero, min/max, hold, damp
Dry air, non-corrosives only
Fluke 718 1G
Range -1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa)
Resolution 0.0001 psi, 0.001 mbar, 0.0001 kPa
Over pressure 5x Full Scale
Functions Zero, Min, Max, Hold, Damp
Fluke 718 30G
Range -12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa)
Resolution 0.001 psi, 0.1 mbar, 0.01 kPa
Over pressure 5x Full Scale
Functions Zero, Min, Max, Hold, Damp
Fluke 718 100G
Range -12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)
Resolution 0.01 psi, 0.1 mbar, 0.01 kPa
Over pressure 2x Full Scale
Functions Zero, Min, Max, Hold, Damp
Fluke 718 300G
Range -12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa)
Resolution 0.01 psi, 1 mbar, 0.1 kPa
Over pressure 375 psi 25 bar
Functions Zero, Min, Max, Hold, Damp
Fluke 718 series via 700 Series Pressure Modules
Range 29 pressure modules, 0 – 1 inH20 to 10,000 psi, 2.5 mbar to 700 bar. Over pressure per pressure module specs
Resolution Per pressure module specs
Accuracy To 0.025% of full span, per pressure module specs
Functions Zero, Min, Max, Hold, Damp
Media compatibility per pressure module specs
Fluke 718 Series Via Built in Pump
Range -12 psi or -850 mbar to full scale Supported Pressure Units; psi, inH20 (4°C), inH20 (20°C), cmH20 (4°C), cmH20 (20°C), bar, mbar, kPa, inHg, mmHg, kg/cm
Loop power range 24 V DC
Accuracy ±10%
Drive; 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V
mA Measure
Range 0 mA to 24 mA
Resolution 0.001 mA
Accuracy 0.015% + 1 count
General Specifications
Maximum voltage 30 volts (non-operating)
Temperature -40°C to 60°C
Operating temperature -10°C to 55°C
Relative humidity 95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C)
Operating altitude 3,000 M max
Shock 1 M drop test
Vibration Random, 2 g, 5 Hz – 500 Hz
Safety CSA C22.2 No. 1010.1: 1992
EMC EN50082-1: 1992 and EN55022: 1994 Class B
Size 216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in)
Weight 992 g (35 oz)
Power, battery life 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718
Battery life 4 to 20 hours typical, depending on functions used
Warranty Three years (one year on pressure pump in Fluke 718)
Display LCD, 5 digit pressure and current simultaneous
For use with non-corrosive gasses

 

ضمانت‌نامه

این دستگاه دارای ضمانت‌نامه سه ساله (یک سال ضمانت برای پمپ فشار) شرکت امروز است. 

متعلقات

این دستگاه شامل لوازم زیر است:

Protective Yellow Holster with test lead storage
Instructions Sheet (14 languages)
Test Leads and Alligator Clip
Two 9V alkaline batteries
NIST - Traceable calibration report and data

کاتالوگ

Fluke 718 Pressure Calibrator